Figure 4. This screen capture illustrates how to configure the MAX6876 for mixed-mode
tracking/sequencing.
7. Consult Table 1 and select the appropriate options for each channel.
Table 1. Channel-Control Options.
Option
Name
Function
100 Ohm
Pull Down
Activates a 100Ω pulldown resistor on the channel's OUT connection during shutdown only.
Overcurrent
Threshold
Activates overcurrent monitoring on the channel. This compares the IN_ voltage to the OUT_
voltage. When OUT_ falls below a percentage of IN_, Overcurrent Threshold asserts the OC
output (bringing it low).
Assert
RESET
Activates this channel's control over the RESET line. If this channel falls below its power-
good threshold, RESET asserts low.
Power
Good
Threshold
When the channel's OUT voltage is within this percentage of the IN voltage, the
corresponding PG pin asserts (goes high impedance).