Secure Microcontroller User’s Guide
42 of 187
DS5001 CRC Register
CRC, 0C1H
R = Unrestricted Read Access, B = Modifiable only via Bootstrap Loader, n = Value after Reset, * = Special: see description
CRC.7-4 RNGE3-0 Determines the range over which a power-up CRC will be performed. Addresses
are specified on 4K boundaries. These bits are reset 0 on a no-V
LI
reset and
unchanged by all other resets.
CRC.0 CRC When set to 1, a CRC check will be performed on power-up or watchdog timeout.
CRC will be checked against stored values. An error will initiate Program Load
mode. These bits are reset 0 on a no-V
LI
reset and unchanged by all other resets.
DS5000 Memory Control Register
MCON, 0C6H
R = Unrestricted Read Access, W = Unrestricted Write Access, T = Timed-access Write Only, B = Modifiable only via Bootstrap Loader,
n = Value after Reset, * = Special: see description
MCON.7-4 PA3–0
Partition Address Selects the starting address of data memory on the bytewide bus. Program space
lies between address 0000h and the partition address. Writes to these bits are only
allowed when PAA = 1. Timed access is not required to write to PA3-0 once PAA
= 1.These bits are set to 1111b on a no-V
LI
reset or when the security lock bit is
cleared by hardware or the bootstrap loader. They are unchanged by all other
resets. These bits are also reset to 1111b when software attempts to modify them
to 0000b when SL = 1 (illegal condition).
PA3 PA2 PA1 PA0 PARTITION ADDRESS
0000h (Invalid when SL = 1)